<p id="">Forney ClearPorts are observation ports for HRSG ducts and hot furnaces, offering an unobstructed view of burner flames and pressure parts downstream. These view ports feature a butterfly-style isolation plate to prevent heat conduction towards the glass, ensuring durability against high temperatures without discoloration.</p><p id="">Available in sizes of 4”, 6”, and 8” for installation on a standard #150 ASME flange.</p>
<p id="">Forney’s MAXFire® HC gas igniter is the perfect solution to reduce operating costs associated with coal firing. Designed to replace existing oil igniters, this Class 1 igniter allows boilers to operate on coal or gas, making it highly versatile. The MAXFire® HC gas igniter is easily installed as a retrofit into a 6" or greater mount tube, and consists of four major components that work together to ensure reliable, stable igniter flame.</p>
<p>Forney’s IDDX Flame Detector Amplifier was specifically designed to easily integrate with any Forney flame detectors in the IDD product line. </p><p>The IDDX model can support push-button switching between multiple detection profiles to avoid excessive downtime in operations with multiple fuel setups.</p>
<p>The DPD detector is a self contained detector with automatic UV or IR tuning capability. Input power and output flame signals are made through a rugged military style connector. In addition to the tuning from the key pad on the rear of the detector, tuning can be accomplished remotely through a computer connection.</p><p></p><p><strong>Important Notice</strong> – <a href="/images/cdn/5e11bc304b55b0f4f5380aa8_DPD-Obsolescence-Ltr.pdf" target="_blank">DPD Obsolescence</a></p>
<p>Forney’s UniFlame® II series flame detectors utilize micro-processor based controllers in conjunction with solid state infrared (IR) and ultraviolet (UV) sensors and dual cell technology for optimal flame detection and discrimination.</p><p></p><p>These self contained flame detectors provide superior detection and discrimination capabilities along with the latest in local or remote tuning capabilities. The detectors have UV and IR sensors for optimum tuning capability. Further tuning enhancements include switchable files with the ability to ratio the two source signals.</p><p></p><p><a href="/images/cdn/5f63775d5b13c2d4f30b0d54_Uniflame%20II%20UV%20-%20IR%20Flame%20Detector.pdf" target="_blank">UniFlame II Advisory</a></p><p><a href="/images/cdn/5e11ba62946b123b75b6ad88_FEX1_Notice.pdf" target="_blank">FEX Product Advisory</a></p>
<p>Our Liquid Fuel Duct Burners inject fuel from the side of the duct to keep the fuel cool until it is burned. An “anchoring” baffle ensures the flame spans the duct to provide even heat distribution.</p><p></p><p>Our patented technology ensures excellent mixing of the turbine exhaust gas and fuel, resulting in clean combustion with reduced CO emissions.</p><p></p><p>Our design eliminates performance variations by using a small amount of external combustion air as opposed to burners that rely solely on turbine exhaust gas for their oxidant.</p>
<p>Forney’s FlameHawk® fiber optic flame detector is a dual channel solid-state device designed for power and industrial gas turbines.</p>
<p id="">Forney provides multiple options to ensure SCR efficiency at lower inlet operating temperatures. Our in-duct, external duct and perimeter fired <a id="" href="https://www.forneycorp.com/burners" target="_blank">burners</a> provide unique solutions for this harsh environment.</p><p id=""></p><p id=""><a href="https://www.powermag.com/scr-reheat-burners-keep-nox-in-spec-at-low-loads/" target="_blank">Check out our article in Power Magazine covering this unique application. </a></p>
<p>The Forney IDD is the most widely used flame detector system in the USA utility market. Its rugged design and reliability, offer many years of service. The combination of a compact detector head connected to a remote, highly tunable amplifier provides the operational flexibility that most utilities need.</p><p></p><p>Forney’s IDD-II Series Flame Detector meets the operational flexibility requirements of utilities through multiple flame detecting and discriminating capabilities.</p><p></p><p><a href="/images/cdn/5e10826e4b55b0050331200d_IDD_Product_Advisory.pdf" target="_blank">IDD Product Advisory</a></p>
<p>Easy configuration allows for many different uses that include: limited space applications, Fresh Air firing,and reheating of process air streams and SCR inlet heating.</p><p></p><p>The standard <a href="https://www.forneycorp.com/burners" target="_blank">burner</a> comes complete with investment castings (stainless steel), high energy ignition and strong supports for long life. We also supply integral frames and distribution grids. Contact Forney with your project specifications.</p><p></p><p>Forney duct burners offer reliable performance and dependability to meet the complex needs of the combined cycle and cogeneration industries.</p>
<p>The IDD 9000 Flame Amplifier is designed for easy upgrade of existing Forney flame amplifiers with most installations simply requiring a flame amplifier replacement and reconnection of existing wires to improve flame detection and discrimination. The IDD 9000 is available in panel or rack mount; single or dual channel configurations. The dual channel configurations use two fully independent channels to support two flame detectors simultaneously</p><p></p>
<p>Forney’s IDD-Ultra Flame Detector is the ideal UV detector for applications with high-temperature requirements.</p><p></p><p>Forney’s Intelligent Dynamic Detector (IDD) – Ultra version is designed to accurately detect and discriminate the radiation produced by the combustion of natural gas or light oil.</p>
<p id="">adVantage Duct Burners perform in the most challenging conditions. Premium components and patented technology join to perform like no other duct burner.</p>
<p>Stack dampers are used to reduce heat loss and prevent rain water from entering your process. Due to the environment these dampers are subject to, it is important that you choose a durable damper from a reliable manufacturer. Forney supplies a complete line of high quality stack dampers to utility and heavy industrial customers. Forney offers both standard size and custom designed stack dampers to meet your plants specific needs.</p><p></p><p>Forney standard sized stack dampers with a flat flange for installation can save you time and money over traditional edge-to-edge type connection.</p>
<p>The Q87 igniter is the best choice when dual fuel (natural gas and No. 2 oil) is required. With a change-out of the internals, the Q87 can switch from firing one fuel to another. It is also the choice when both air and steam atomization is required for No. 2 oil. The Q87 is 4 inches in diameter with a self-stabilizing diffuser and a high energy spark igniter.</p><p></p><p>Th e Q-87 oil or gas igniter off ers a fully self-contained fl exible solution for robust and reliable burner ignition, stabilization and warm-up.</p><p></p>
<p>Proven Performance. Stable Operation.</p><p>With its unique air mixing technique, the Forney PAF-II Low NOx Burner reduces NOx formation in a simple yet effective manner. The PAF-II Low NOx burner produces low NOx emissions through the dynamic interaction of the flame, combustion air and furnace combustion products. The foundation of the PAF-II design is the injection of a high velocity air stream around an inner core of low velocity air that both stages the air but also recirculates the products of combustion back into the flame which reduces the flame temperature.</p>
<p>Forney Parallel Air Flow (PAF) burners are custom engineered for a wide range of heat inputs while providing the flexibility of firing a variety of fuel types.</p>
<p>The DURAFire® air atomized No. 2 oil igniter features the only “protected primary combustion zone” design on the market. As a result this igniter is self-stabilized, highly reliable and requires virtually no maintenance. Atomization takes place at the rear of the igniter away from the heat of the tip resulting in no fouling or need for cleaning. Most applications require no igniter retraction reducing installation costs and ongoing maintenance.</p><p></p><p>The DURAFire® oil igniter delivers the most reliable source of energy for main flame ignition, flame stabilization, and boiler warm-up.</p>
<p>The MAXFire® 100 Series gas igniter incorporates the “protected primary combustion zone” design in each of the 5 capacities available. The ignition process starts inside the guide tube away from the burner environment resulting in an extremely stable and reliable igniter. Capacities (nominal) range from 1 mmBtu/hr to 50 mmBtu/hr.</p><p></p><p>MAXFire® gas igniters provide the most reliable source of energy for main flame ignition, flame stabilization, and boiler warm-up.</p>
<p>For HRSG bypass applications, Forney provides a better, faster, cheaper alternative to a typical flap and guillotine damper arrangement.<br>Forney utilizes two BiPlane Dampers for superior isolation and control. One damper on the inlet to the HRSG and the other damper isolating the stack.</p><p></p><p>Read more in our article:<br><a href="/newsletter/hrsg-bypass-dampers" target="_blank">HRSG Bypass Dampers – Eliminating the Flap</a></p><div data-rt-embed-type='true'><iframe class="product-yt" src="https://www.youtube.com/embed/mfBb7a9y3Rk" title="YouTube video player" frameborder="0" allow="accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture" allowfullscreen></iframe></div>
<p>The Forney Horn Igniter is designed to be a direct replacement for the OEM igniter on tangentially fired boilers. This igniter features improvements such as the high energy spark igniter (HESI), optical flame detector and the ignition air distribution ring. These three features combine to produce a highly reliable igniter. The HESI produces a consistent spark due to its foul resistant design, while the optical detector proves flame without physical contact.</p><p></p><p>Forney’s Horn Igniter offers reliable single or dual fuel ignition and warm-up for tangentially fired burners and is designed for maximum flame stability and detection.</p><p></p><p>Designed for maximum flame stability on tangentially fired burners, Forney’s Horn Igniter offers reliable single or dual fuel ignition and warm-up.</p>
<p>The HESI is a Class 3 Igniter used for direct spark ignition of oil or gas igniters, small burners, and combustion turbines. The Standard HESI is FM approved and the CE Version meets the Low Voltage Directive and Electromagnetic Interference Immunity Directive. An ATEX version is also available.</p><p></p><p>Forney’s High Energy Spark Igniter (HESI) provides a highly reliable, non-fouling source of ignition for oil or gas igniters or small burners.</p>
<p>Forney’s HD Flame Detector is the best available flame detector for the Power Generation, Petrochemical and Industrial markets. It provides the highest level of flame discrimination in multi-burner applications with an easy to use interface on a mobile app.</p>
<p>This Class I igniter is located in a tilting tangentially fired boiler adjacent to the main fuel nozzle.</p><p></p><p>As an oil igniter, the unique rear atomizer results in a single tube extending to the one piece tip. This design eliminates the need for atomizer maintenance.</p><p></p><p>As a gas igniter, the gas is directed to the tip through the single flexible tube. Stabilization is maintained by a 7.5 inch swirler which creates a low pressure zone just down stream of the nozzle. Combustion air is provided from the windbox.</p><p></p><p>Forney’s Flexible Single Tube (FST) Igniter provides multi-fuel, stable and reliable ignition for tangential burners utilizing a flexible design for optimal ignition with tilting nozzles.</p>
<p>The Forney high performance, severe service expansion joint is designed to take the most extreme movements without inducing unneeded loads onto the adjacent duct.</p>
<p id="">Forney in Conjunction with <a href="https://www.stormeng.com/eagle-air-ii-coal-natural-gas-co-fire-burner/" target="_blank">Storm Technologies</a> brings you the Eagle Air II Burner!</p><p id=""></p><p id="">Need the ability to fire both coal or natural gas so your plant can take advantage of the most cost effective fuel option? Eagle Air II is a Wall-Fired-Boiler Dual-Fuel Burner that gives you that flexibility.</p>
<p id="">The Forney Blower Skid Assembly supplies cooling and/or combustion air to igniters, detectors, or any other equipment that requires low-pressure air.</p>
<p id="">The BiPlane™ Louver provides superior function over tradition double louver damper designs. The BiPlane design provides zero leak sealing when control or isolation is needed.</p>